BIOTEC CENTRE PICRA Member' company - ACTIVITIES - DOMAINS OF EXPERTISE
Image analysis : monkey brain Automated blood center CRO Bioanalysis using Mass Spectrometry Elderly subjects are also studied
Biotec Centre : PICRA Member' company
 
Domains of expertise : Bioanalysis using Mass Spectrometry
BIOANALYSIS using Mass Spectrometry
BIOANALYSIS using Mass Spectrometry

FIVE MASS-SPECTROMETER APPARATUS (SCIEX, Thermo-electron)
LC-Mass Mass spectrometry (in tandem) : SCIEX API's 4000, THERMO Ultra, access to Ion Trap.
The team is experienced with ion-paired volatile mobile phases and in coupling techniques LC-Mass.

Compound

Validated limit of quantitation

nicotine ..................................................................
morphine ...............................................................
cocaine ..................................................................
melatonin ..............................................................
selegilin .................................................................
various polypeptides ...............................................
numerous antibiotics ..............................................
250 pg/mL of plasma
1 pg/mL of plasma & e.c.fluid
500 pg/mL of plasma
1 pg/mL of plasma
100 pg/mL of plasma
20 - 50 pg/mL of plasma
100 pg/mL of plasma

Matching of Triple-quad with Ion-Trap equipment’s provides powerful methodologies for structural metabolism involvements.
Use of multiprobe II for spe automatisation.

Deuterated internal standardsDeuterated internal standards
For all the compounds studied at BIOTEC CENTRE, a team of chemists synthesises deuterated compounds as internal standards. This team is also highly involved in synthesis of haptens for immunochemistry as well as synthesis of potential metabolites.

Contact : Norbert BROMET, Maguy BROMET-PETIT, Ph.D. and Jordan Gonçalves


BIOANALYSIS using UV, ECD & others


LC - coupled to UV, Fluo, Radio, ECDLC - coupled to UV, Fluo, Radio, ECD
All software’s are GLP compliant with audit trail (EZ chrom-Elite from VWR, Flo-One from Packard/Perkin Elmer)

LC - coupled to UV, Fluo, Radio, ECD

LC - coupled to UV, Fluo, Radio, ECDFLO-One radioactive detection
A radio-chromatogram example

FLO-One radioactive detection results

 

LC - coupled to UV, Fluo, Radio, ECDFLO-One radioactive detection

QC follow-up during the time course of a study

Contact : Maguy BROMET-PETIT, Ph.D.

BIOTEC CENTRE - 10, avenue Claude Guillemin - 45071 Orléans Cedex 2 Biotec centre laboratory France - Phone : +(33) 2 38 76 20 60 - Fax : +(33) 2 38 76 20 59 - Contact E-mail